Product Brief

  • Introduction

    This ELISA kit is based on the principle of competitive binding between E2 in the test specimen and E2 enzyme conjugate for a constant amount of anti-Estradiol polyclonal antibody. In the incubation, anti-E2 antibody coated wells are incubated with E2 standards, controls, samples, and E2 enzyme conjugate at room temperature for 60 minutes. During the incubation, a fixed amount of HRPlabeled E2 competes with the endogenous E2 in the standard, sample, or quality control serum for a fixed number of binding sites of the specific E2 antibody. E2 peroxidase conjugate immunologically bound to the well progressively decreases as the concentration of E2 in the specimen increases. Unbound E2 peroxidase conjugate is then removed and the wells are washed. Next, a solution of TMB Reagent is added and incubated at room temperature for 30 minutes, resulting in the development of blue color. The color development is stopped with the addition of stop solution, and the absorbance is measured spectrophotometrically at 450 nm. A standard curve is obtained by plotting the concentration of the standard versus the absorbance

    Overview

    Product Name Mouse Rat Estradiol ELISA Kit
    SKU/Catalog Number EK7003
    Description Competitive High Sensitivity ELISA kit for Quantitative Detection of Mouse/Rat Estradiol. 96wells/kit, with removable strips.
    Cite This Product Mouse Rat Estradiol ELISA Kit (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK7003)
    Validated Species Mouse, Rat
    Application ELISA

    *Our Boster Guarantee covers the use of this product in the above tested applications.

    Cross Reactivity There is no detectable cross-reactivity.
    Pack Size 96wells/kit, with removable strips.

    Properties

    Sensitivity 3 pg/ml
    *Sensitivity, or Lower Limit of Detection (LLD), is the minimum level of target protein the ELISA assay can detect. We measure 20 blank wells and if the O.D. value is 2 standard deviations higher than the blanks' average O.D. the sample can be deemed positive.
    Assay Range 3-300 pg/ml
    *This assay range is determined using common samples. For samples with low target protein concentrations, users can adjust the standard curve to extend the lower limit of assay range.
    Sample Type Serum and plasma

    *The above listed samples are the ones valided with the assay. If you do not see your sample of interest listed, as long as there is enough level of target protein present in the sample, this Picokine? ELISA kit should detect it. 
    **For protocol and tips regarding preparing your sample of interest, please check our ELISA sample preparation guide.
    Storage Store the kit at 2°C to 8°C. Keep microwells sealed in a dry bag with desiccants. The reagents are stable until expiration of the kit. Do not expose reagent to heat, sun, or strong light. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)

    Kit Components

    Description Quantity
    Microwells coated with polyclonal anti-Estradiol Antibody 12x8x1 Microwells
    Estradiol Standards 6 vials ( ready to use) 0.5 ml
    Estradiol Enzyme conjugate Concentrate, 20X 1 vial 0.7ml
    Assay Diluent 1 bottle (ready to use) 12ml
    TMB Reagent 1 bottle (ready to use) 12ml
    Stop Solution 1 bottle (ready to use) 12ml
    20X Wash concentrate 1 bottle 25ml

    Material Required But Not Provided

    1. Distilled or deionized water

    2. Precision pipettes

    3. Disposable pipette tips. Multichannel pipettes are recommended in the condition of large amount of samples in the detection.

    4. ELISA reader capable of reading absorbance at 450nm

    5. Absorbance paper or paper towel

    6. Graph paper

    Background

    Estradiol E2 is the most potent natural Estrogen, produced mainly by the ovary, placenta, and in smaller amounts by the adrenal cortex, and the male testes. Estradiol is secreted into the blood stream where 98% bound to sex hormone binding globulin (SHBG). Estrogenic activity is effected via estradiol-receptor complexes which trigger the appropriate response at the follicles, uterus, breast, vagina, urethra, hypothalamus, pituitary and to a lesser extent the liver and skin. In non-pregnant women with normal menstrual cycles, estradiol secretion follows a cyclic, biphasic pattern with the highest concentration found immediately prior to ovulation. During pregnancy, maternal serum Estradiol levels increase considerably, to well above the pre-ovulatory peak levels and high levels are sustained throughout pregnancy. Serum Estradiol measurements are a valuable index in evaluating a variety of menstrual dysfunctions such as precocious or delayed puberty in girls and primary and secondary amenorrhea and menopause. Estradiol levels have been reported to be increased in patients with feminizing syndromes, gynaecomastia and testicular tumors. In cases of infertility, serum Estradiol measurements are useful for monitoring induction of ovulation following treatment.

    Mouse Rat Estradiol ELISA Kit Images

    Click the images to enlarge.

Instructions

WARNINGS AND PRECAUTIONS

1. For Research Use Only. Not for use in diagnostic procedures.

2. Potential biohazardous materials: The calibrator and controls contain human source components, which have been tested and found non-reactive for hepatitis B surface antigen as well as HIV antibody with FDA licensed reagents. However, there is no test method that can offer complete assurance that HIV, Hepatitis B virus or other infectious agents are absent. These reagents should be handled at the Biosafety Level 2, as recommended in the Centers for Disease Control/National Institutes of Health manual, "Biosafety in Microbiological and Biomedical Laboratories" 1984.

3. Do not pipette by mouth. Do not smoke, eat, or drink in the areas in which specimens or kit reagents are handled.

4. The components in this kit are intended for use as an integral unit. The components of different lots should not be mixed.

5. It is recommended that standards, control and serum samples be run in duplicate.

6. Optimal results will be obtained by strict adherence to this protocol. Accurate and precise pipetting, as well as following the exact time and temperature requirements prescribed are essential. Any deviation from this may yield invalid data.

7. Do not use sodium azide as preservative. Sodium azide inhibits HRP enzyme activities.

SPECIMEN COLLECTION HANDLING

1. Collect blood specimens and separate the serum immediately.

2. Typically, specimens may be stored refrigerated at (2°C to 8°C) for 5 days. If storage time exceeds 5 days, store frozen at (-20°C) for up to one month.

3. Avoid multiple freeze-thaw cycles.

4. Prior to assay, frozen sera should be completely thawed and mixed well.

5. Do not use grossly lipemic specimens.

REAGENT PREPARATION

20X Enzyme conjugate: Prepare 1X working solution at 1:20 with assay diluent (e.g. Add 0.1ml of the E2 enzyme conjugate concentrate to 1.9ml of assay diluent)


Wash Buffer: Prepare 1X Wash Buffer by adding the contents of the bottle (25 ml, 20X) to 475 ml of distilled or deionized water. Store at room temperature (20-25°C).

ASSAY PROCEDURE

1. Bring all reagents to room temperature (20-25°C) before use.

2. Secure the desired number of coated wells in the holder.

3. Dispense 25 ul of standards, specimens and controls into appropriate wells.

4. Dispense 100 ul of working reagent of Estradiol enzyme conjugate into each well.

5. Mix well by placing on shaker for 10 – 20 seconds.

6. Incubate at room temperature (20-25°C) for 120 minutes.

7. Remove liquid from all wells. Wash wells three times with 300 uL of 1X wash buffer. Blot on absorbance paper or paper towel.

8. Dispense 100 ul of TMB Reagent into each well. Gently mix for 10 seconds.

9. Incubate at room temperature (20-25°C) for 30 minutes.

10. Stop the reaction by adding 50 ul of Stop Solution to each well.

11. Gently mix 30 seconds. It is important to make sure that all the blue color changes to yellow color completely.

12. Read absorbance at 450 nm with a microplate reader within 15 minutes.

CALCULATION OF RESULTS

The standard curve is constructed as follows:

1. Calculate the mean absorbance value (A450) for each set of reference standards, controls and samples.

2. Construct a standard curve by plotting the mean absorbance obtained for each reference standard against its concentration in pg/ml on a linear-linear graph paper, with absorbance values on the vertical or Y axis, and concentrations on the horizontal or X axis.

3. Use the mean absorbance values for each specimen to determine the corresponding concentration of Estradiol in pg/ml from the standard curve.

4. Any values obtained for diluted samples must be further converted by applying the appropriate dilution factor in the calculations.