The Bosterbio OneStep Human Prolactin(PRL) Pre-Coated ELISA (Enzyme-Linked Immunosorbent Assay) kit is a solid phase immunoassay specially designed to measure Human Prolactin(PRL) with a 96-well strip plate that is pre-coated with antibody specific for Prolactin(PRL). The detection antibody is a HRP conjugated antibody specific for Prolactin(PRL). The capture antibody is monoclonal antibody from mouse, the detection antibody is monoclonal antibody from mouse. The kit is analytically validated with ready to use reagents. To measure Human Prolactin(PRL), add standards and samples to the wells, then add the HRP conjugated detection antibody. Wash away the unbounded protein and HRP conjugated detection antibody. TMB is substrate to HRP and will be catalyzed to produce a blue color product, which changes into yellow after adding acidic stop solution. Upon addition of the substrate, the density of the yellow product is linearly propotional to Human Prolactin(PRL) in the sample. Read the density of the yellow product in each well using a plate reader, and benchmark the sample wells' readings against the standard curve to determine the concentration of Human Prolactin(PRL) in the sample. For more information on assay principle, protocols, and troubleshooting tips, see Boster's ELISA Resource Center at https://www.bosterbio.com/elisatechnical-resource-center.
Product Name | Human Prolactin(PRL) OneStep ELISA Kit |
---|---|
SKU/Catalog Number | EK7006 |
Description | Sandwich High Sensitivity ELISA kit for Quantitative Detection of Human Prolactin(PRL). 96wells/kit, with removable strips. |
Cite This Product | Human Prolactin(PRL) OneStep ELISA Kit (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK7006) |
Validated Species | Human |
Application | ELISA *Our Boster Guarantee covers the use of this product in the above tested applications. **For positive and negative control design, consult "Tissue specificity" under Protein Target Info. |
Cross Reactivity | There is no detectable cross-reactivity. |
Pack Size | 96wells/kit, with removable strips. |
Sensitivity | 50 μIU/mL *Sensitivity, or Lower Limit of Detection (LLD), is the minimum level of target protein the ELISA assay can detect. We measure 20 blank wells and if the O.D. value is 2 standard deviations higher than the blanks' average O.D. the sample can be deemed positive. |
---|---|
Assay Range | 40-2000 μIU/mL *This assay range is determined using common samples. For samples with low target protein concentrations, users can adjust the standard curve to extend the lower limit of assay range. |
Sample Type | Serum *The above listed samples are the ones valided with the assay. If you do not see your sample of interest listed, as long as there is enough level of target protein present in the sample, this Picokine? ELISA kit should detect it. **For protocol and tips regarding preparing your sample of interest, please check our ELISA sample preparation guide. |
Storage | Store the kit at 2°C to 8°C. Keep microwells sealed in a dry bag with desiccants. The reagents are stable until expiration of the kit. Do not expose reagent to heat, sun, or strong light. Avoid multiple freeze-thaw cycles(Shipped with wet ice.) |
Description | Quantity | Volume | Buffers |
Anti-Human Prolactin(PRL) Pre-coated 96-well strip microplate | 1 | 8 strips of 12 wells | Anti- Prolactin(PRL) monoclonal antibody, Polystyrene micro-well plate |
Human Prolactin(PRL) Standards(S0~S5) | 6 | 0.5ml | Prolactin(PRL) (0, 40, 100, 300, 800, 2000 μIU/mL), 0.02M PBS, 20% new-born calf serum, 0.1% Proclin-300 |
HRP Conjugated anti-Human Prolactin(PRL) antibody | 1 | 6ml | HRP Conjugated anti-Human Prolactin(PRL) antibody, 0.02M PBS, 20% new-born calf serum, 0.1% Proclin-300, 0.01% azophloxine |
Controls | 2 | 0.5ml | Prolactin(PRL), 100% natural protein, 0.1% Proclin-300 |
20X Wash Buffer Concentrate | 1 | 15ml | 0.2M PBS containing 0.5% tween 20 |
Color Developing Reagent A | 1 | 7ml | 11m mol/L Urea hydrogen peroxide |
Color Developing Reagent B | 1 | 7ml | 2m mol/L 3,3'5,5’-Tetramethylbenzidine |
Stop Solution | 1 | 7ml | 2mol/L Sulphuric acid |
Plate Sealers | 2 | Piece |
1. Microplate Reader capable of reading absorbance at 450nm.
2. Automated plate washer (optional)
3. Pipettes and pipette tips capable of precisely dispensing 0.5 μl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples.
4. Deionized or distilledwater.
5. 500ml graduated cylinders.
6. Test tubes for dilution.
You can check the tissue specificity below for information on selecting positive and negative control.
Gene Name | PRL |
---|---|
Protein Function | Human prolactin (lactogenic hormone) is a single chain polypeptide hormone with a molecular weight of approximately 23,000 daltons. Prolactin is secreted from the anterior pituitary gland in both men and woman. Women normally have slightly higher basal prolactin levels than men. During and following pregnancy, prolactin, in association with other hormones, stimulates breast development and milk production. Hypersecretion of prolactin can be caused by pituitary tumors, hypothalamic diseases, hypothyroidm, renal failure, acute exercise and several medications. Hyperprolactinemia inhibits hypogonadism in men and women with accompanying low FSH and LH levels. |
Subcellular Localization | Secreted. |
Uniprot ID | P01236 |
Reseach Areas | Growth Factors/Hormones, Lipid Metabolism, Metabolism, Protein Phosphorylation, Receptor Tyrosine Kinases, Signal Transduction, Tyrosine Kinases| |
*if product is indicated to react with multiple species, protein info is based on the human gene.
Human prolactin (lactogenic hormone) is a single chain polypeptide hormone with a molecular weight of approximately 23,000 daltons. Prolactin is secreted from the anterior pituitary gland in both men and woman. Women normally have slightly higher basal prolactin levels than men. During and following pregnancy, prolactin, in association with other hormones, stimulates breast development and milk production. Hypersecretion of prolactin can be caused by pituitary tumors, hypothalamic diseases, hypothyroidm, renal failure, acute exercise and several medications. Hyperprolactinemia inhibits hypogonadism in men and women with accompanying low FSH and LH levels.
Click the images to enlarge.
Human Prolactin(PRL) ELISA Kit standard curve.
1. For Research Use Only. Not for use in diagnostic procedures.
2. Potential biohazardous materials: The calibrator and controls contain human source components, which have been tested and found non-reactive for hepatitis B surface antigen as well as HIV antibody with FDA licensed reagents. However, there is no test method that can offer complete assurance that HIV, Hepatitis B virus or other infectious agents are absent. These reagents should be handled at the Biosafety Level 2, as recommended in the Centers for Disease Control/National Institutes of Health manual, "Biosafety in Microbiological and Biomedical Laboratories" 1984.
3. Do not pipette by mouth. Do not smoke, eat, or drink in the areas in which specimens or kit reagents are handled.
4. The components in this kit are intended for use as an integral unit. The components of different lots should not be mixed.
5. It is recommended that standards, control and serum samples be run in duplicate.
6. Optimal results will be obtained by strict adherence to this protocol. Accurate and precise pipetting, as well as following the exact time and temperature requirements prescribed are essential. Any deviation from this may yield invalid data.
7. Do not use sodium azide as preservative. Sodium azide inhibits HRP enzyme activities.
1. Collect blood specimens and separate the serum immediately.
2. Typically, specimens may be stored refrigerated at (2°C to 8°C) for 5 days. If storage time exceeds 5 days, store frozen at (-20°C) for up to one month.
温馨提示:因厂家更改产品包装、产地或者更换随机附件等没有任何提前通知,且每位咨询者购买情况、提问时间等不同,为此以下回复仅对提问者3天内有效,其他网友仅供参考!若由此给您带来不便请多多谅解,谢谢!
服务热线
0771-3293894