Human Luteinizing Hormone (LH) OneStep ELISA Kit 96T

价:
4537.00
价:
¥4537.00

号:EK7067

牌:BOSTER 博士德

账期 货到付款

EA (预计5-7工作日到货)

工作时间

周一至周五:9:00-18:00

咨询电话

0771-3293894

在线咨询

客服 郭恒 蔡玉坤 曾宪飞 技术咨询

浏览了该商品的用户还浏览了

点击查看说明

Product Brief

  • Introduction

    The Bosterbio OneStep Human Luteinizing Hormone(LH) Pre-Coated ELISA (Enzyme-Linked Immunosorbent Assay) kit is a solid phase immunoassay specially designed to measure Human Luteinizing Hormone(LH) with a 96-well strip plate that is pre-coated with antibody specific for Luteinizing Hormone(LH). The detection antibody is a HRP conjugated antibody specific for Luteinizing Hormone(LH). The capture antibody is monoclonal antibody from mouse, the detection antibody is monoclonal antibody from mouse. The kit is analytically validated with ready to use reagents. To measure Human Luteinizing Hormone(LH), add standards and samples to the wells, then add the HRP conjugated detection antibody. Wash away the unbounded protein and HRP conjugated detection antibody. TMB is substrate to HRP and will be catalyzed to produce a blue color product, which changes into yellow after adding acidic stop solution. Upon addition of the substrate, the density of the yellow product is linearly propotional to Human Luteinizing Hormone(LH) in the sample. Read the density of the yellow product in each well using a plate reader, and benchmark the sample wells' readings against the standard curve to determine the concentration of Human Luteinizing Hormone(LH) in the sample. For more information on assay principle, protocols, and troubleshooting tips, see Boster's ELISA Resource Center at https://www.bosterbio.com/elisatechnical-resource-center.

    Overview

    Product Name Human Luteinizing Hormone (LH) OneStep ELISA Kit
    SKU/Catalog Number EK7067
    Description Sandwich High Sensitivity ELISA kit for Quantitative Detection of Human Luteinizing Hormone(LH). 96wells/kit, with removable strips.
    Cite This Product Human Luteinizing Hormone (LH) OneStep ELISA Kit (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK7067)
    Validated Species Human
    Application ELISA

    *Our Boster Guarantee covers the use of this product in the above tested applications.

    Cross Reactivity There is no detectable cross-reactivity.
    Pack Size 96wells/kit, with removable strips.

    Properties

    Sensitivity 0.5 IU/L
    *Sensitivity, or Lower Limit of Detection (LLD), is the minimum level of target protein the ELISA assay can detect. We measure 20 blank wells and if the O.D. value is 2 standard deviations higher than the blanks' average O.D. the sample can be deemed positive.
    Assay Range 2-75 IU/L
    *This assay range is determined using common samples. For samples with low target protein concentrations, users can adjust the standard curve to extend the lower limit of assay range.
    Sample Type Serum

    *The above listed samples are the ones valided with the assay. If you do not see your sample of interest listed, as long as there is enough level of target protein present in the sample, this Picokine? ELISA kit should detect it. 
    **For protocol and tips regarding preparing your sample of interest, please check our ELISA sample preparation guide.
    Storage Store the kit at 2°C to 8°C. Keep microwells sealed in a dry bag with desiccants. The reagents are stable until expiration of the kit. Do not expose reagent to heat, sun, or strong light. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)

    Kit Components

    Description Quantity Volume Buffers
    Anti-Human Luteinizing Hormone(LH) Pre-coated 96-well strip microplate 1 8 strips of 12 wells Anti- Luteinizing Hormone(LH) monoclonal antibody, Polystyrene micro-well plate
    Human Luteinizing Hormone(LH) Standards(S0~S5) 6 - Luteinizing Hormone(LH) (0, 2, 5, 20, 40, 75IU/L), 0.02M PBS, 20% new-born calf serum, 0.1%Proclin-300
    HRP Conjugated anti-Human Luteinizing Hormone(LH) antibody 1 6ml HRP Conjugated anti-Human Luteinizing Hormone(LH) antibody, 0.02M PBS, 20% new-born calf serum, 0.01% azophloxine
    Controls 2 - Luteinizing Hormone(LH), 100% natural protein, 0.1%Proclin-300
    Color Developing Reagent A 1 7ml 11m mol/L Urea hydrogen peroxide
    Color Developing Reagent B 1 7ml 2m mol/L 3,3'5,5’-Tetramethylbenzidine
    Stop Solution 1 7ml 2mol/L Sulphuric acid
    Plate Sealers 2 Piece

    Material Required But Not Provided

    1. Microplate Reader capable of reading absorbance at 450nm.

    2. Automated plate washer (optional)

    3. Pipettes and pipette tips capable of precisely dispensing 0.5 ?l through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples.

    4. Deionized or distilledwater.

    5. 500ml graduated cylinders.

    6. Test tubes for dilution.

    Human Luteinizing Hormone (LH) OneStep ELISA Kit Images

    Click the images to enlarge.

     Human Luteinizing Hormone(LH) ELISA Kit standard curve

    Human Luteinizing Hormone(LH) ELISA Kit standard curve

Instructions

WARNINGS AND PRECAUTIONS

1. For Research Use Only. Not for use in diagnostic procedures. 
2. For laboratory use. 
3. Potential biohazardous materials: The calibrator and controls contain human source components which have been tested and found non-reactive for hepatitis B surface antigen as well as HIV antibody with FDA licensed reagents. However, there is no test method that can offer complete assurance that HIV, Hepatitis B virus or other infectious agents are absent. These reagents should be handled at the Biosafety Level 2, as recommended in the Centers for Disease Control/National Institutes of Health manual, "Biosafety in Microbiological and Biomedical Laboratories" 1984. 
4. Do not pipette by mouth. Do not smoke, eat, or drink in the areas in which specimens or kit reagents are handled. 
5. Components in this kit are intended for use as an integral unit. Components of different lots should not be mixed. 
6. It is recommended that standards, control and serum samples be run in duplicate. 
7. Optimal results will be obtained by strict adherence to this protocol. Accurate and precise pipetting, as well as following the exact time and temperature requirements prescribed are essential. Any deviation from this may yield invalid data.

SPECIMEN COLLECTION AND HANDLING

1. Collect blood specimens and separate the serum immediately. 
2. Typically, specimens may be stored refrigerated at (2-8. C) for 5 days. If storage time exceeds 5 days, store frozen at (-20°C) for up to one month. 
3. Avoid multiple freeze-thaw cycles. 
4. Prior to assay, frozen sera should be completely thawed and mixed well. 
5. Do not use grossly lipemic specimens.

REAGENT PREPARATION

Prepare 1X Wash buffer by adding the contents of the bottle (25 ml, 20X) to 475 ml of distilled or deionized water. Store at room temperature (20-25. C).

ASSAY PROCEDURE

Prior to assay, bring all reagents to room temperature. Gently mix all reagents before use. 
1. Place the desired number of coated strips into the holder 
2. Pipette 25ul of LH standards, control and patient's sera. 
3. Add 100ul of Conjugate Reagent to all wells. Mix plate by placing on a plate shaker at 600rpm for 30 seconds. 
4. Incubate for 60 minutes at room temperature (20-25°C). 
5. Remove liquid from all wells. Wash wells three times with 300ul of 1X wash buffer. Blot on absorbent paper towels. 
6. Add 100ul of TMB substrate to all wells. 
7. Incubate for 15 minutes at room temperature. 
8. Add 50ul of stop solution to all wells. Shake the plate gently to mix the solution. 
9. Read absorbance on ELISA Reader at 450 nm within 15 minutes after adding the stopping solution.

CALCULATION OF RESULTS

1. Reliable And Reproducible Results Will Be Obtained When The Assay Procedure Is Carried Out With A 
1. Check LH standard value on each standard vial. This value might vary from lot to lot. Make sure you check the value on every kit. See example of the standard attached. 
3. To construct the standard curve, plot the absorbance for Cotinine standards (vertical axis) versus the LH standard concentrations (horizontal axis) on a linear graph paper. Draw the best curve through the points. 
3. Read the absorbance for controls and each unknown sample from the curve. Record the value for each control or unknown sample.

LIMITATION OF THE TEST

1. Do not use sodium azide as preservative. Sodium azide inhibits HRP enzyme activities.


温馨提示:因厂家更改产品包装、产地或者更换随机附件等没有任何提前通知,且每位咨询者购买情况、提问时间等不同,为此以下回复仅对提问者3天内有效,其他网友仅供参考!若由此给您带来不便请多多谅解,谢谢!