Product Brief

  • Introduction

    The Bosterbio OneStep Human Insulin Pre-Coated ELISA (Enzyme-Linked Immunosorbent Assay) kit is a solid phase immunoassay specially designed to measure Human Insulin with a 96-well strip plate that is pre-coated with antibody specific for Insulin. The detection antibody is a HRP conjugated antibody specific for Insulin. The capture antibody is monoclonal antibody from mouse, the detection antibody is monoclonal antibody from mouse. The kit is analytically validated with ready to use reagents. To measure Human Insulin, add standards and samples to the wells, then add the HRP conjugated detection antibody. Wash away the unbounded protein and HRP conjugated detection antibody. TMB is substrate to HRP and will be catalyzed to produce a blue color product, which changes into yellow after adding acidic stop solution. Upon addition of the substrate, the density of the yellow product is linearly propotional to Human Insulin in the sample. Read the density of the yellow product in each well using a plate reader, and benchmark the sample wells' readings against the standard curve to determine the concentration of Human Insulin in the sample. For more information on assay principle, protocols, and troubleshooting tips, see Boster's ELISA Resource Center at https://www.bosterbio.com/elisatechnical-resource-center.

    Overview

    Product Name Human Insulin OneStep ELISA Kit
    SKU/Catalog Number EK7000
    Description Sandwich High Sensitivity ELISA kit for Quantitative Detection of Human Insulin. 96wells/kit, with removable strips.
    Cite This Product Human Insulin OneStep ELISA Kit (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK7000)
    Validated Species Human
    Application ELISA

    *Our Boster Guarantee covers the use of this product in the above tested applications.

    **For positive and negative control design, consult "Tissue specificity" under Protein Target Info.

    Cross Reactivity There is no detectable cross-reactivity.
    Pack Size 96wells/kit, with removable strips.

    Properties

    Sensitivity 2.0 mIU/L
    *Sensitivity, or Lower Limit of Detection (LLD), is the minimum level of target protein the ELISA assay can detect. We measure 20 blank wells and if the O.D. value is 2 standard deviations higher than the blanks' average O.D. the sample can be deemed positive.
    Assay Range 10-100 mIU/L
    *This assay range is determined using common samples. For samples with low target protein concentrations, users can adjust the standard curve to extend the lower limit of assay range.
    Sample Type Serum

    *The above listed samples are the ones valided with the assay. If you do not see your sample of interest listed, as long as there is enough level of target protein present in the sample, this Picokine? ELISA kit should detect it. 
    **For protocol and tips regarding preparing your sample of interest, please check our ELISA sample preparation guide.
    Storage Store the kit at 2°C to 8°C. Keep microwells sealed in a dry bag with desiccants. The reagents are stable until expiration of the kit. Do not expose reagent to heat, sun, or strong light. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)

    Kit Components

    Description Quantity Volume Buffers
    Anti-Human Insulin Pre-coated 96-well strip microplate 1 8 strips of 12 wells Anti-Insulin monoclonal antibody, Polystyrene micro-well plate
    Human Insulin Standards(S1~S5) 5 - Insulin(10,16,30,60,100mIU/L), 0.02M PBS, 20% new-born calf serum, 0.1%Proclin-300
    HRP Conjugated anti-Human Insulin antibody 1 6ml HRP Conjugated anti-Human Insulin antibody, 0.02M PBS, 20% new-born calf serum, 0.01% azophloxine, 0.1%Proclin-300
    Controls 2 - 100% natural protein, 0.1%Proclin-300
    20X Wash Buffer Concentrate 1 15ml 0.2M PBS containing 0.5% tween 20
    Color Developing Reagent A 1 7ml 11m mol/L Urea hydrogen peroxide
    Color Developing Reagent B 1 7ml 2m mol/L 3,3'5,5’-Tetramethylbenzidine
    Stop Solution 1 7ml 2mol/L Sulphuric acid
    Plate Sealers 2 Piece

    Material Required But Not Provided

    1. Microplate Reader capable of reading absorbance at 450nm.

    2. Automated plate washer (optional)

    3. Pipettes and pipette tips capable of precisely dispensing 0.5 ?l through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples.

    4. Deionized or distilledwater.

    5. 500ml graduated cylinders.

    6. Test tubes for dilution.

    Protein Target Info (Source: Uniprot.org)

    You can check the tissue specificity below for information on selecting positive and negative control.

    Gene Name INS
    Protein Name Insulin
    Protein Function Insulin decreases blood glucose concentration. It increases cell permeability to monosaccharides, amino acids and fatty acids. It accelerates glycolysis, the pentose phosphate cycle, and glycogen synthesis in liver. Functions as a hormone belonging to the insulin family.
    Subcellular Localization Secreted.
    Uniprot ID P01308
    Reseach Areas Cell Biology|

    *if product is indicated to react with multiple species, protein info is based on the human gene.

    Background for Insulin

    Insulin decreases blood glucose concentration. It increases cell permeability to monosaccharides, amino acids and fatty acids. It accelerates glycolysis, the pentose phosphate cycle, and glycogen synthesis in liver. Functions as a hormone.

    Human Insulin ELISA Kit Images

    Click the images to enlarge.

     <span style=Human Insulin ELISA Kit standard curve. ">

     Human Insulin ELISA Kit standard curve.

Instructions

WARNINGS AND PRECAUTIONS

1. For Research Use Only. Not for use in diagnostic procedures.

2. Potential biohazardous materials: The calibrator and controls contain human source components, which have been tested and found non-reactive for hepatitis B surface antigen as well as HIV antibody with FDA licensed reagents. However, there is no test method that can offer complete assurance that HIV, Hepatitis B virus or other infectious agents are absent. These reagents should be handled at the Biosafety Level 2, as recommended in the Centers for Disease Control/National Institutes of Health manual, "Biosafety in Microbiological and Biomedical Laboratories" 1984.

3. Do not pipette by mouth. Do not smoke, eat, or drink in the areas in which specimens or kit reagents are handled.

4. The components in this kit are intended for use as an integral unit. The components of different lots should not be mixed.

5. It is recommended that standards, control and serum samples be run in duplicate.

6. Optimal results will be obtained by strict adherence to this protocol. Accurate and precise pipetting, as well as following the exact time and temperature requirements prescribed are essential. Any deviation from this may yield invalid data.

7. Do not use sodium azide as preservative. Sodium azide inhibits HRP enzyme activities.

SPECIMEN COLLECTION HANDLING

1. Collect blood specimens and separate the serum immediately.

2. Typically, specimens may be stored refrigerated at (2°C to 8°C) for 5 days. If storage time exceeds 5 days, store frozen at (-20°C) for up to one month.

3. Avoid multiple freeze-thaw cycles.

-->