Qiagen 凯杰 Biosharp Omega

首页信号传导Millipore 密理博>

图片仅供参考,请以实物为准
收藏

Milliplex Catalog ID.APOMAG-62K-02.Human Apolipoprotein MAG

价:
0.00
价:
¥0.00

号:APOMAG-62K-02

牌:Millipore 密理博

账期 货到付款

EA (预计3-5工作日到货)

亲,想了解价格请QQ咨询客服!

工作时间

周一至周五:9:00-18:00

咨询电话

0771-3293894

在线咨询

客服 郭恒 蔡玉坤 曾宪飞 技术咨询

浏览了该商品的用户还浏览了

Replacement Information

重要规格表

Analytes Available Species Reactivity Key Applications Detection Methods
Apo AI, Apo AII, Apo B, Apo CII, Apo CIII, Apo E H Mplex Luminex xMAP
Description
Catalogue Number APOMAG-62K
Trade Name
  • MILLIPLEX
Description MILLIPLEX MAP Human Apolipoprotein Magnetic Bead Panel - Cardiovascular Disease Multiplex Assay
Background Information Metabolic Syndrome has received increased attention from the medical community with more and more cases of obesity, type 2 diabetes and cardiovascular diseases being described and studied. To help researchers better understand the complexities of metabolic syndrome and cardiovascular disease, Millipore is pleased to offer the Human Apolipoprotein magnetic bead panel that will measure any combination of 6 analytes, including Apo AI, Apo AII, Apo B, Apo CII, Apo C III and Apo E.
References
Product Information
Detection method Luminex xMAP
Configuration Design your multiplex kit by choosing available analytes within this panel.
Precision, %
  • Inter-assay: <20
  • Intra-assay: <10
Panel Type MAGNETIC Cardiovascular
Applications
Application This MILLIPLEX MAP Human Apolipoprotein Magnetic Panel is a Cardiovascular Disease multiplex assay. The analytes available for this multiplex kit are: Apo AI, Apo AII, Apo B, Apo CII, Apo CIII, Apo E.
Key Applications
  • Multiplexing
Application Notes • This kit may be used for the analysis of Human Apolipoproteins in Human serum, plasma, tissue culture supernatant or other biological samples
• Sample dilutions for serum and plasma are recommended at 1: 4,000
• The assay can be performed in less than 3 hours
Biological Information
Species Reactivity
  • Human
Analytes Available
  • Apo AI
  • Apo AII
  • Apo B
  • Apo CII
  • Apo CIII
  • Apo E
Cross Reactivity To test cross-reactivity among the assays in the panel, individual apolipoprotein standard was prepared at a concentration 4 times greater than the highest concentration in the calibration curve and tested in the 6-plex assays with multiplexed beads containing immobilized capture antibodies and individual detection antibodies. There was negligible cross-reactivity within the panel.
Accuracy
  • Apo AI 86%
  • Apo AII 91%
  • Apo B 92%
  • Apo CII 92%
  • Apo CIII 89%
  • Apo E 85%
Physicochemical Information
Sensitivity
  • Apo AI 1.48 ng/mL
  • Apo AII 1.00 ng/mL
  • Apo B 4.84 ng/mL
  • Apo CII 1.22 ng/mL
  • Apo CIII 1.71 ng/mL
  • Apo E 1.42 ng/mL
Linearity of Dilution Contact technical support for this information.
Standard Curve Range
  • Refer to the kit protocol for details.
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Usage Statement
  • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Storage and Shipping Information
Packaging Information
Material Size 96-well plate
Transport Information
Supplemental Information
Specifications

温馨提示:因厂家更改产品包装、产地或者更换随机附件等没有任何提前通知,且每位咨询者购买情况、提问时间等不同,为此以下回复仅对提问者3天内有效,其他网友仅供参考!若由此给您带来不便请多多谅解,谢谢!

我要咨询

咨询内容:
支付方式 货到付款 账期付款

服务热线

0771-3293894