Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Apoptosis is a normal physiologic process that occurs during embryonic development as well as in maintenance of tissue homeostasis. The apoptotic program is characterized by certain morphologic features, including loss of plasma membrane asymmetry and attachment, condensation of the cytoplasm and nucleus, and internucleosomal cleavage of DNA. Loss of plasma membrane asymmetry is one of the earliest features. In apoptotic cells, the membrane phospholipid phosphatidylserine (PS) is translocated from the inner to the outer leaflet of the plasma membrane, thereby exposing PS to the external cellular environment. Annexin V is a 35-36 kDa Ca2+ dependent phospholipid-binding protein that has a high affinity for PS, and binds to cells with exposed PS. Annexin V may be conjugated to fluorochromes including BD Horizon BV605. This format retains its high affinity for PS and thus serves as a sensitive probe for flow cytometric analysis of cells that are undergoing apoptosis. Since externalization of PS occurs in the earlier stages of apoptosis, BV605 Annexin V staining can identify cells undergoing apoptosis at an earlier stage rather than assays based on nuclear changes such as DNA fragmentation.
BV605 Annexin V staining precedes the loss of membrane integrity which accompanies the latest stages of cell death resulting from either apoptotic or necrotic processes. Therefore, staining with BV605 Annexin V is typically used in conjunction with a vital dye such as 7-Amino-Actinomycin (7-AAD) to allow the investigator to identify early apoptotic cells (BV605 Annexin V positive, 7-AAD negative). Viable cells with intact membranes exclude 7-AAD, whereas the membranes of dead and damaged cells are permeable to the nucleic acid dye, 7-AAD. For example, cells that are considered viable are both BV605 Annexin V negative and 7-AAD negative while cells that are in early apoptosis are BV605 Annexin V positive and 7-AAD negative. Cells that are in late apoptosis or already dead are both BV605 Annexin V positive and 7-AAD positive. This assay does not distinguish between cells that have undergone apoptotic death versus those that have died as a result of a necrotic pathway because in either case, the dead cells will stain with both BV605 Annexin V and 7-AAD. However, when apoptosis is measured over time, cells can be often tracked from being BV605 Annexin V negative and 7-AAD negative (viable, or no measurable apoptosis), to BV605 Annexin V positive and 7-AAD negative (early apoptosis, membrane integrity is present), and finally to BV605 Annexin V positive and 7-AAD positive (end stage apoptosis and death). The movement of cells through these three stages suggests apoptosis. In contrast, a single observation indicating that cells are both BV605 Annexin V and 7-AAD positive, by itself reveals less information about the process by which the cells underwent their demise.
The Annexin V is conjugated to BD Horizon BV605 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 407-nm and Em Max of 602-nm, BD Horizon BV605 can be excited by a violet laser and detected with a standard 610/20-nm filter set. BD Horizon BV605 is a tandem fluorochrome of BD Horizon BV421 and an acceptor dye with an Em max at 605-nm. Due to the excitation of the acceptor dye by the green (532 nm) and yellow-green (561 nm) lasers, there will be significant spillover into the PE and BD Horizon PE-CF594 detectors off the green or yellow-green lasers. BD Horizon BV605 conjugates are very bright, often exhibiting brightness equivalent to PE conjugates and can be used as a third color off of the violet laser.
BV605 is a tandem fluorochrome that combines BD Horizon BV421 and an acceptor dye with an Em max at 602-nm. These conjugates are very bright, often exhibiting similar brightness to equivalent PE conjugates. Due to the excitation of acceptor dye by the green (532-nm) and yellow-green (561-nm) lasers, there will be significant spillover into the PE and BD Horizon PE-CF594 detectors off the green or yellow-green lasers.
温馨提示:因厂家更改产品包装、产地或者更换随机附件等没有任何提前通知,且每位咨询者购买情况、提问时间等不同,为此以下回复仅对提问者3天内有效,其他网友仅供参考!若由此给您带来不便请多多谅解,谢谢!
服务热线
0771-3293894