Human Biomarker Premixed Mag Luminex Performance Assay Kit A 8 Plexes

价:
25916.00
价:
¥25916.00

号:FCSTM13-08

牌:R&D Systems

账期 货到付款

EA (预计7-14工作日到货(以R&D Systems官网货期为准))

工作时间

周一至周五:9:00-18:00

咨询电话

0771-3293894

在线咨询

客服 郭恒 蔡玉坤 曾宪飞 技术咨询

浏览了该商品的用户还浏览了

  • Assay Type
    Magnetic bead-based multiplex assay for the Luminex® MAGPIX® platform
  • Format
    96-well microplate and antibody-coated magnetic beads*
  • Analytes Detected
    Please see table below.
  • Performance Validation
     
    Product Features
    • Simultaneously detect multiple analytes
    • Magnetic format allows for easier wash steps
    • User selects specific analytes of interest
    • Requires small sample size
    • Undergoes similar validation testing as Quantikine® ELISA Kits
    • Precise and Specific

Analytes

Select analytes you would like to measure from the list below. Please note that analytes with the same bead region are not compatible in the same assay and when selected will populate a new assay after clicking the "continue" button.

** Initial Starting Dilutions

* Note: This analyte is in more than one assay. Please refer to the Technical Datasheet for information specific to this analyte.

 

Base Kit Contents
  • Standard Cocktail(s)
  • Antibody-coated magnetic bead cocktails
  • Biotinylated detection antibody cocktail
  • Bead Diluent
  • Biotin Antibody Diluent
  • Calibrator Diluent(s)
  • Streptavidin-PE
  • Wash Buffer Concentrate
  • Mixing Bottles
  • Round-bottom Microplate
  • Foil Plate Sealers

 

Bead Set Contents
  • Antibody-coated magnetic beads
  • Biotinylated detection antibody

 

Information for Compatible Analytes

For performance data for the different analyte-specific beads, please see product datasheets for the compatible individual Bead Sets.

Analyte Catalog Number Sensitivity
(pg/mL)
High Standard
Value* (pg/mL)
Microparticle
Region
BAFF/BLyS/TNFSF13B 0.56 2530 13
CCL20/MIP-2 alpha 0.11 1,890 19
CD14 20 141,300 14
CD25/IL-2 R alpha 0.45 7,650 20
CD27/TNFRSF7 3.23 14,900 34
CXCL13/BLC/BCA-1 LBAM801 0.56 2,120 36
Gp130 12 89,440 15
IL-6 R alpha 1.01 12,100 30
TNF RII LUCAM726 0.2 870 25

*A standard curve must be generated each time an assay is run, utilizing values from the Standard Value Card included in the Base Kit.

 

Validated Samples and Recommended Starting Dilution
Analyte Cell Culture
Supernate
Serum EDTA
Plasma
Heparin Plasma
BAFF/BLyS/TNFSF13B 1:2 1:3 1:3 1:3
CCL20/MIP-2 alpha 1:2 1:3 1:3 1:3
CD14 1:2 1:50 1:50 1:50
CD25/IL-2 R alpha 1:2 1:3 1:3 1:3
CD27/TNFRSF7 1:2 1:3 1:3 1:3
CXCL13/BLC/BCA-1 1:2 1:3 1:3 1:3
Gp130 1:2 1:50 1:50 1:50
IL-6 R alpha 1:2 1:50 1:50 1:50
TNF RII 1:2 1:50 1:50 1:50

N/R=This sample type is not recommended for use in this assay

*CD40 Ligand is present in platelet granules and is released upon platelet activation. Therefore, to measure circulating levels of CD40 Ligand, platelet-free plasma should be collected for measurement.

 

More Information About Magnetic Bead-based Multiplex Kits For The Luminex ® Platform

Magnetic are designed for use with the Luminex MAGPIX CCD Imager. Alternatively, kits can be used with the Luminex 100/200 or Bio-Rad® Bio-Plex®, dual laser, flow-based sorting and detection platforms.

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. One laser is bead-specific and determines which analyte is being detected. A magnet in the analyzer captures and holds the superparamagnetic microparticles in a monolayer. Two spectrally distinct Light Emitting Diodes (LEDs) illuminate the beads. One LED identifies the analyte that is being detected and the second LED determines the magnitude of the PE-derived signal, which is in direct proportion to the amount of analyte bound. Each well is imaged with a CCD camera. Kits can also be used with Luminex 100/200 or a Bio-Rad Bio-Plex dual laser, flow-based systems.

 

Assays for the Luminex platform are offered as or . The Luminex High Performance Assays are fully validated panels with a focused selection of analytes. They are available in We Mix, You Mix, and Predetermined formats. The Luminex Assays allows for the maximum number of analytes in a multiplex and is supplied as a premixed kit. .

Trademarks and registered trademarks are the property of their respective company.