Total Nitric Oxide and Nitrate/Nitrite Parameter SixPak 1 PK

价:
26973.00
价:
¥26973.00

号:SKGE001

牌:R&D Systems

账期 货到付款

EA (预计7-14工作日到货(以R&D Systems官网货期为准))

工作时间

周一至周五:9:00-18:00

咨询电话

0771-3293894

在线咨询

客服 郭恒 蔡玉坤 曾宪飞 技术咨询

浏览了该商品的用户还浏览了

  • Format
    96-well strip plate
  • Assay Length
    < 1 hour
  • Sample Type & Volume Required Per Well
    Cell Culture Supernates (10 uL), Serum (25 uL), EDTA Plasma (25 uL), Heparin Plasma (25 uL), Citrate Plasma (25 uL), Urine (10 uL)
  • Sensitivity
    0.78 umol/L
  • Assay Range
    3.1 - 200 umol/L (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine)
  • Specificity
    Measures Total Nitric Oxide, Nitrite and Nitrate levels in various samples
  • Cross-reactivity
    < 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
  • Interference
    Interference observed with other substances.
Control Available
QC135, Parameter Immunoassay Control Set 904 for Nitrite -
QC134, Parameter Immunoassay Control Set 849 for Nitrate -
Product Summary
The Parameter Total Nitric Oxide kit has two assay options. Endogenous nitrite is measured in the first option. In the second option, nitrate is converted to nitrite using nitrate reductase and total nitrite is measured. To obtain the nitrate concentration, endogenous nitrite is subtracted from the total nitrite value.

Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.
Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine
Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean 30 77.2 138 31.5 79.9 138.7
Standard Deviation 0.76 1.1 2.2 1.46 2.91 4.78
CV% 2.5 1.4 1.6 4.6 3.6 3.4

Recovery

The recovery of the nitrate standard spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Supernates (Nitrite Assay) (n=10) 107 91-115
Plasma (Nitrate Assay) (n=25) 98 87-110
Plasma (Nitrite Assay) (n=20) 104 92-117
Serum (Nitrate Assay) (n=10) 95 89-101
Serum (Nitrite Assay) (n=10) 109 98-118
Urine (Nitrite Assay) (n=10) 101 87-112
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of the nitrate standard were serially diluted with the Reaction Diluent to produce samples with values within the dynamic range of the assay.
Total Nitric Oxide and Nitrate/Nitrite Parameter Assay Kit
Preparation and Storage
  • Storage
    Store the unopened product at 2 - 8 °C. Do not use past expiration date.
  • Alternate Names
    Nitric Oxide;

温馨提示:因厂家更改产品包装、产地或者更换随机附件等没有任何提前通知,且每位咨询者购买情况、提问时间等不同,为此以下回复仅对提问者3天内有效,其他网友仅供参考!若由此给您带来不便请多多谅解,谢谢!