Qiagen 凯杰 Biosharp Omega

首页蛋白检测与定量R&D Systems>

图片仅供参考,请以实物为准
收藏

Human Magnetic Luminex Performance Assay Base Kit, MMP Panel 1 KT

价:
7962.00
价:
¥7962.00

号:LMPM000

牌:R&D Systems

账期 货到付款

EA (预计7-14工作日到货(以R&D Systems官网货期为准))

工作时间

周一至周五:9:00-18:00

咨询电话

0771-3293894

在线咨询

客服 郭恒 蔡玉坤 曾宪飞 技术咨询

浏览了该商品的用户还浏览了

  • Assay Type
    Magnetic bead-based multiplex assay for the Luminex® MAGPIX® platform
  • Format
    96-well microplate and antibody-coated magnetic beads*
  • Analytes Detected
    Please see table below.
  • Performance Validation
    For standard curves, intra-assay and inter-assay precision, recovery, and linearity data for the different analyte-specific beads, please see product datasheets for corresponding individual Bead Sets (below).

Analytes

Select analytes you would like to measure from the list below. Please note that analytes with the same bead region are not compatible in the same assay and when selected will populate a new assay after clicking the "continue" button.

** Initial Starting Dilutions

* Note: This analyte is in more than one assay. Please refer to the Technical Datasheet for information specific to this analyte.

 

* Antibody-coated beads supplied in compatible Bead Sets, sold separately (see below).

 

Product Features
  • Simultaneously detect multiple analytes
  • Magnetic format allows for easier wash steps
  • User selects specific analytes of interest
  • Requires small sample size
  • Undergoes similar validation testing as Quantikine® ELISA Kits
  • Precise and Specific

 

Base Kit Contents
  • Standard Cocktail(s)
  • Bead Diluent
  • Biotin Antibody Diluent
  • Calibrator Diluent(s)
  • Streptavidin-PE
  • Wash Buffer Concentrate
  • Mixing Bottles
  • Round-bottom Microplate
  • Foil Plate Sealers

 

Bead Set Contents
  • Antibody-coated magnetic beads
  • Biotinylated detection antibody

 

Information for Compatiable Analytes

For performance data for the different analyte-specific beads, please see product datasheets for the compatible individual Bead Sets.

Analyte Catalog
Number
Sensitivity
(pg/mL)
High Standard Value*
(pg/mL)
Microparticle
Region
EMMPRIN 5.6 25,700 30
MMP-1 1.1 18,300 20
MMP-2 12.6 63,100 19
MMP-3 7.3 25,700 21
MMP-7 6.6 55,850 22
MMP-8 16.6 59,700 25
MMP-9 13.7 73,100 26
MMP-10 3.2 31,000 27
MMP-12 0.7 6,700 28
MMP-13 63.5 324,000 29

*A standard curve must be generated each time an assay is run, utilizing values from the Standard Value Card included in the Base Kit.

 

Validated Samples and Recommended Starting Dilution

Analyte Cell Culture
Supernate
Serum Heparin
Plasma
Platelet-poor
Heparin Plasma
Saliva Urine
EMMPRIN 1:5 1:5* 1:5* 1:5* 1:40 1:10
MMP-1 1:5 1:5 1:5 1:5 1:40 1:10
MMP-2 N/R 1:50 1:50 1:50 1:40 1:10
MMP-3 1:5 1:5 1:5 1:5 1:40 1:10
MMP-7 1:5 1:5 1:5 1:5 1:40 1:10
MMP-8 1:5 1:50 1:50 1:50 1:40 1:10
MMP-9** 1:5 1:50 N/R 1:50 1:40 1:10
MMP-10 1:5 1:5 1:5 1:5 1:40 1:10
MMP-12 1:5 1:50 1:50 1:50 1:40 1:10
MMP-13 1:5 1:5 N/R N/R 1:40 1:10

N/R=This sample type is not recommended for use in this assay

*When assaying serum and plasma samples, EMMPRIN cannot be multiplexed with MMP-7, MMP-8, MMP-10, MMP-12, or MMP-13.

**MMP-9 is present in platelet granules and released upon platelet activation. Therefore, to measure circulating levels of this factor, platelet-free plasma should be collected for measurement.

 

More Information about Magnetic Bead-Based Multiple Kits for the Luminex Platform

Magnetic multiplex kits are designed for use with the CCD Imager. Alternatively, kits can be used with the or Bio-Rad® Bio-Plex®, dual laser, flow-based sorting and detection platforms.

Analyte-specific antibodies are pre-coated onto color-coded magnetic microparticles. Microparticles, standards and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, streptavidin-phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated antibody, is added to each well. A final wash removes unbound Streptavidin-PE, the microparticles are resuspended in buffer and read using the Luminex MAGPIX Analyzer. A magnet in the analyzer captures and holds the superparamagnetic microparticles in a monolayer. Two spectrally distinct Light Emitting Diodes (LEDs) illuminate the beads. One LED identifies the analyte that is being detected and the second LED determines the magnitude of the PE-derived signal, which is in direct proportion to the amount of analyte bound. Each well is imaged with a CCD camera. Kits can also be used with Luminex 100/200 or a Bio-Rad Bio-Plex dual laser, flow-based systems.

Trademarks and registered trademarks are the property of their respective company.